DESCRIPTION. INVOS 5100C? cerebral somatic oximeter, available in two or four data channels, is the only noninvasive oximeter which provides simultaneous monitoring of the brain and body through up to four data channels.

The INVOS system is the clinical standard in regional oximetry, providing clinicians with reliable, timely, and actionable cerebral and somatic monitoring. Description of Symbols The noninvasive INVOS Cerebral Somatic Oximeter is intended for use as an adjunct trend monitor of regional hemoglobin oxygen saturation of blood in the brain of an individual. Oct 27, 2013 Cerebral oximetry based on nearinfrared spectroscopy (NIRS) is increasingly used during the perioperative period of cardiovascular operations.

It is a noninvasive technology that can monitor the regional oxygen saturation of the frontal cortex. Current literature indicates that it can stratify The INVOS system assumes a ratio of 75 venous blood to 25 arterial blood.

Other regional oximeters assume a venous: arterial ratio of 70: 30. The 5 difference in the arterial assumption and the 5 venous assumption causes a relative bias. The INVOS System is designed to noninvasively, directly and continuously measure and monitor changes in the approximate regional hemoglobin oxygen saturation in the blood in the brain of an individual.

The noninvasive INVOS 51 OOC is intended for use as an adjunct trend monitor of regional hemoglobin oxygen saturation. of blood in The INVOS system is the only cerebralsomatic oximetry system with improved outcome claims.

([FOOTNOTEMurkin JM, Adams SJ, Novick RJ, et al. Monitoring brain oxygen saturation during coronary bypass surgery: a randomized, prospective study. Operations Manual INVOS System, Model 5100C WHENEVER THIS SYMBOL IS SEEN ON THE DEVICE, THIS MANUAL SHOULD BE CONSULTED FOR A COMPLETE EXPLANATION.

SomaSensor: Trademark name for disposable sensor for use with the INVOS Cerebral Somatic Oximeter OxyAlert NIRSensor: Trademark name for disposable sensor for use with the INVOS Cerebral The Clinical Utility of Cerebral Oximetry Monitoring Edwin G.

Avery, IV, M. D.C. P. I. (Somanetics INVOS) assumes a ratio of 75: 25 of venous to arterial blood ratio in the measured sample, while Signal processing algorithms in the cerebral oximeter Surgical and Critical Care Applications of the INVOS Cerebral Oximeter Detection and Correction of Brain Oxygen Imbalance 66 rSO 2 75 12 BL SSI 1 L.

Detection and Correction of Brain Oxygen Imbalance Surgical and Critical Care Applications of the INVOS Cerebral Oximeter A Pocket Guide for Clinicians Harvey L. Edmonds, Jr. The INVOS 5100B is identical to the INVOS 5100 AdultPediatric Cerebral Oximeter System (K ) and the SSFB Somatic SomaSensor is identical to the SAFB (KO ) except that it is supplied with a larger adhesive pad and revised labeling.